Portable power station · Power stations
BLUETTI AC180
US specs for the BLUETTI AC180: 1,152 Wh, 1,800 W of AC, LiFePO4, four 120 V outlets, and what 2,700 W Power Lifting Mode is for.
- Used for estimates
- 1,152 Wh
- Rated AC output
- 1,800 W
- Power Lifting Mode
- 2,700 W
- Chemistry
- LiFePO4
- Region on this page
- United States, 120 V
- Specs last checked
- 2026-11-18
| Spec | Figure used here |
|---|---|
| Capacity | 1,152 Wh |
| Rated AC output | 1,800 W. Four AC outlets, 120 V, 15 A, 1,800 W total, pure sine wave, from the US product page. |
| Power Lifting Mode | 2,700 W |
| Chemistry | LiFePO4 |
| AC outlets | Four AC outlets, 120 V, 15 A, 1,800 W total, pure sine wave, from the US product page. Rated watts ÷ 120 V is 15 A. The outlet is listed at 15 A. This site uses 15 A as the continuous current limit, the lower of those figures. |
| USB-C | One port, 100 W maximum. |
| USB-A | Two pairs. Each pair is 5 V, 3 A, 15 W total. |
| Car port | 12 V, 10 A, regulated. |
| Wireless pad | 15 W maximum. |
The AC180 on this page is the 1,152 Wh model. BLUETTI’s product page also sells an AC180P at 1,440 Wh in the same comparison table. Do not mix them. The estimates that name the AC180 use 1,152 Wh.
What 1,800 W and 2,700 W mean
The output block says four 120 V, 15 A outlets, 1,800 W in total, pure sine wave, and surge power of 2,700 W. The hero line calls the 2,700 W figure Power Lifting Mode. The FAQ is specific: that mode is for high-power heating devices, and it says not to use it to run an air conditioner or a washing machine.
A pairing with a motor compares the running load with 1,800 W and with the 15 A outlet. It does not clear a “yes” by pointing at 2,700 W. A heater that BLUETTI has already described as a Power Lifting load is a different page, and it is not one of the starter pairings.
The marketing block on the product page lists an air conditioner at 8,100 BTU among example loads. It does not print that air conditioner’s watts. This site does not turn that example into a wattage. The window-air-conditioner page uses Frigidaire’s own spec sheets.
BLUETTI’s runtime example, kept separate
BLUETTI’s FAQ writes the running time as battery capacity × DoD × efficiency ÷ (load power + self-consumption). For the AC180 they say DoD is 90%, efficiency is 85%, and self-consumption is about 15 W. Their worked example is a 100 W blender:
1,152 Wh × 0.90 × 0.85 ÷ (100 W + 15 W) ≈ 7.66 hours.
They also say that formula is not suitable for inductive loads with compressors, such as refrigerators and air conditioners, and that the data is for reference only. This site’s pairings do not use the 90% or the 15 W. They use 1,152 × 0.85 so a reader can compare the AC180 with a Jackery or an EcoFlow on the same rule. You can redo BLUETTI’s version from the numbers above whenever you want their version.
Chemistry and the other limits on the same page
The battery block says 1,152 Wh and LiFePO4, with 3,500 or more cycles to 80% of original capacity. Cycle life is not extra runtime tonight.
The page also disagrees with itself about weight: one line says about 37 lb, and the spec table says about 16 kg (35.27 lb). Weight is not used in any estimate. Trust the label on the unit if you are lifting it.
Discharging above 30°C is listed at 1,500 W maximum rather than 1,800 W. A hot room can lower the output the table shows. The pairing pages use 1,800 W and do not silently switch to 1,500 W. If the station is hot, the real limit may be the lower one BLUETTI printed.
Pairings that use this station
Questions people ask
Is 2,700 W the surge for a sump pump or an air conditioner?
BLUETTI's spec table lists surge power of 2,700 W. The FAQ on the same page says Power Lifting Mode runs high-power heating devices up to 2,700 W, such as space heaters, hair dryers, and electric blankets, and says not to use the unit that way for an air conditioner or a washing machine. This site treats 2,700 W as Power Lifting for heating loads, not as motor-start headroom.
Why doesn't this site use BLUETTI's own runtime formula?
BLUETTI's FAQ example is capacity × 90% depth of discharge × 85% efficiency, divided by load plus about 15 W of self-consumption. This site uses capacity × 0.85 only, on every station, and says so. Using both formulas at once would stack two discounts. Their example is quoted here so you can rerun it.